عربي

 

Central computer

Central computer  -  Information Systems

Components of central computer

·   3 Units of power supply devices with the capacity of
(K.V.A 30.20.20) and a ground well for protection
from lightning and power outages.

·   SERVER ITANUM HP INTEGRITY RX 7640.

·   Each cabinet contains 2 servers.

·   Each server contains 2 partitions.

·   Each partition works as independent server with
a 1.6 GHZ, 18 MB Cash and 8GB Memory.

·   All servers are connected with fiber cables to
San Switch of EVA8000 cabinet.

·   All the 4 servers are clustered.

·   Used operation system is OPEN_VMS; 8.3.

·   ORACLE RDB 7.3 database.

·   Storage area network cabinet with 1TB capacity
contains Data Protector for automatic data pack up.

Automate Reading Meters, billing and Installments system

·    Automate reading meters, piling and installments system over all customers sectors (house-private-governorate-public-public groups-public parties) as a primary phase in order to convert all current meters into electronic read meters.

·         Benefits of Automating

-   Get the real reading of the real consumption of the month according to specific reading plan.

-    Avoid human mistakes of recording the reading.

-    Raise billing and installments rate as well as the raise of the readers' performance.

-   Reduction of customers complains.

-  Control supervision over readers, collectors, and inspectors. 

 

Components of the first phase system

                                                               

    Individual Shipper.               Multi-Connections Unit.                          Portable Reading Unit.     

Components of the second phase system

Aims 

·         Avoid human reading of the meters.

·         A more reading rate of the meters.

·         Automatic accurate reading of meters.

Way of Implementation

·         Makes an electronic and mechanical design for the electronic meter unit.

·         Establish a lab to prepare and test meters.

·         Equip portable computer unit with a probe for remote electronic reading of remote meters.

·         Develop current meters and convert them into electronic meters.

Print Bills and Lists Phase

·         Prepare printing files to print 500.000 bill monthly
     using laser printers.

·         Print lists of billing according to daily itinerary of
    the collector.

·         Print list of inoperative meters monthly.

·         Print all reports of collectors and billing to measure
     the performance level.

 

Customer Service and Hot Line

 

Receive customers complains through the hot line 125
and all branches of the company are connected by Avaya System
to search complains and answer them.

 

Information network

A network to connect computers together, to do the following:

Exchange daily information database online throughout network depends
on VPN   FRAMRELAY ANEY TO ANEY, with a 512 kb/s DSL line for
each branch and 8GB DSL line for the head quarters.

1-   ROWTER CISCO 1800  4 PORT   8 MB.

2-   SHDSL device to connect the company with the head quarters of Telecom Egypt.

3-   A number of Cabinets to distribute internet connection to all administrative users.

4-   ROWTER CISCO 1800 1 PORT   512 KB.

- Establish ISDN information network system to connect branches, stores, labs and units of the company with the head quarters using central Database Online System at 64 Kb/s.

- Develop information network using frame Relay Connection at 512 Kb/s connection and up to 2Mb for branches and 16Mb for the head quarters.

1-   ADSL Router to connect with the Internet Service Provider.

2-   Increase IP Addresses number up to 256 virtual IP Addresses By the technicians of the company.

3-   The advantage of this ADSL service is it connected 24 hours/day at 1Mb instead of dialup at 56 Kb/s. As we call can distribute internet connections to all branches of the company all over Beheira governorate with no additional costs.

 

 Copyrights (C)  2008 - Behiera Water & Drainage Company